Competency information
Details
Control infection risks in accordance with departmental protocols.
Considerations
- Protocols and requirements for hygiene and infection control related to the relevant range of procedures, including preparation, conduct and completion of procedure.
- Protocol for hand washing and how effective hand washing contributes to control of infection.
Relevant learning outcomes
# | Outcome |
---|---|
# 1 | Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with single chamber bradycardia, recognising the clinical signs and symptoms of device complications. |
# 2 | Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with single chamber tachycardia, recognising the clinical signs and symptoms of device complications. |
# 3 | Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with dual chamber bradycardia, recognising the clinical signs and symptoms of device complications. |
# 4 | Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with dual chamber tachycardia, recognising the clinical signs and symptoms of device complications. |
# 5 | Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with CRT-P (cardiac resynchronization therapy with pacemaker), recognising the clinical signs and symptoms of device complications. |
# 6 | Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with CRT-D (cardiac resynchronization therapy with defibrillator function) recognising the clinical signs and symptoms of device complications. |
# 7 | Outcome Perform long-term follow-up procedures for patients with implanted cardiac devices, ensuring the safe and effective functioning of each device and highlighting devices that may need replacement. |