Competency information

Details

Take appropriate action to respond to the specific needs of the patient, as defined by department protocol.

Considerations

  • Recognition of the contraindications to testing prior to the test, as defined by department protocol.
  • The range of needs of people with disabilities within a typical care pathway for a patient with cardiac disease and cardiac arrhythmias.

Relevant learning outcomes

# Outcome
# 1 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with single chamber bradycardia, recognising the clinical signs and symptoms of device complications.
# 2 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with single chamber tachycardia, recognising the clinical signs and symptoms of device complications.
# 3 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with dual chamber bradycardia, recognising the clinical signs and symptoms of device complications. 
# 4 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with dual chamber tachycardia, recognising the clinical signs and symptoms of device complications.
# 5 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with CRT-P (cardiac resynchronization therapy with pacemaker), recognising the clinical signs and symptoms of device complications.
# 6 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with CRT-D (cardiac resynchronization therapy with defibrillator function) recognising the clinical signs and symptoms of device complications.
# 7 Outcome Perform long-term follow-up procedures for patients with implanted cardiac devices, ensuring the safe and effective functioning of each device and highlighting devices that may need replacement.