Competency information

Details

Set up appropriate equipment in preparation for each type of procedure, including resuscitation equipment where appropriate. Calibrate where necessary.

Considerations

  • Range of equipment used, relative merits and principles of measurement, including:
    • recognition of the errors or potential risks of using defective equipment in clinical practice and the implications of use
    • the application of relevant troubleshooting skills
    • identification of common faults and remedial action
    • current safety standards, including safety testing and routine maintenance
    • requirements for set-up and calibration specific to that procedure

Relevant learning outcomes

# Outcome
# 1 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with single chamber bradycardia, recognising the clinical signs and symptoms of device complications.
# 2 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with single chamber tachycardia, recognising the clinical signs and symptoms of device complications.
# 3 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with dual chamber bradycardia, recognising the clinical signs and symptoms of device complications. 
# 4 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with dual chamber tachycardia, recognising the clinical signs and symptoms of device complications.
# 5 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with CRT-P (cardiac resynchronization therapy with pacemaker), recognising the clinical signs and symptoms of device complications.
# 6 Outcome Perform and interpret procedures to assess implanted cardiac devices and, using appropriate algorithms, program and optimise the device to monitor or provide treatment appropriate to patients with CRT-D (cardiac resynchronization therapy with defibrillator function) recognising the clinical signs and symptoms of device complications.
# 7 Outcome Perform long-term follow-up procedures for patients with implanted cardiac devices, ensuring the safe and effective functioning of each device and highlighting devices that may need replacement.